Contractor Guide
StormSnipe·

Field Guide to Documenting Soft-Metal Hail Damage: Gutters & Trim

Stepwise field protocols to record soft-metal hail damage on gutters, HVAC caps, flashings, and trim. Photo angles, scale refs, GPS/EXIF, and sample notes.

Soft-metal dents in gutters and trim often read as surface scuffs on a fast walk-around. Inspectors who move slowly capture evidence that holds up to adjuster review.

Why focus on soft-metal components

Gutters, HVAC caps, flashings, and trim are thin-gauge metal. They deform rather than shatter. Dents can be under 1.0 inch but still compromise water flow and sealing. Recordable indicators include deformation, paint loss exposing substrate, creasing, splitting at fasteners, and displaced seam closures.

Field teams should document four measurable items for each component: dent diameter, dent depth or roof-attachment offset, exact location on the component, and a clear context photo linking the defect to the structure.

Standard measurement and scale protocol

  1. Use a caliper or small ruler to measure dent diameter to the nearest 0.125 inch. Record the measurement in the notes. If using a coin reference, use the NWS object scale values for common coins: penny = 0.75 inch, quarter = 1.00 inch. State the inch value as well as the object name.

  2. Photograph a close-up with a scale card or coin placed adjacent to the dent. Place the scale on the same plane as the dent. Do not let the scale obscure the damage.

  3. When possible measure dent depth or offset. For gutters, measure vertical offset from the original plane to the dented plane at the deepest point. Record to the nearest 1/16 inch.

  4. Record distance from a fixed roof reference. Example entry: "Gutter north elevation, 12 ft east of downspout A, dent centered on hanger strap, 1.00 in diameter, 3/32 in depth."

  5. Note material and finish. Example: "26-gauge K-style aluminum, painted white, 2012 installation estimated."

Photo protocol and angles

Capture a four-photo set for each distinct damage site.

  • Wide context shot. Show the defect relative to the roofline, downspout, or HVAC unit. Include a portion of the yard or driveway for landmarking.
  • Medium shot. Frame the damaged component fully, including adjacent seams and fasteners. Capture how water would flow past the defect.
  • Close-up with scale. Coin or scale card on same plane. Natural light or LED work lights to reduce shadow. Parallel camera plane to metal plane to avoid foreshortening.
  • Detail of attachment points. Fastener heads, rivets, seam crimps, and caulk joints.

File naming: use a consistent pattern. Example format: YYYYMMDD_site_street_component_seq.jpg. Embed the location and timestamp in the filename and preserve EXIF data.

GPS, EXIF, and timestamp standards

Enable location services on inspection devices. Confirm the phone or camera time is synchronized to network time. Record GPS coordinates to five decimal places for each damage cluster. That precision maps to roughly 1 m horizontal.

When EXIF is stripped by a transfer app, export a CSV line for each photo with the filename, latitude, longitude, and device timestamp. Example CSV row: 20250612_1723_123main_gutter_01.jpg, 35.46789, -97.51623, 2025-06-12T17:23:18Z.

Document inspection start and end times for each structure. Note any obstruction that prevented closer inspection, such as vegetation or a locked fence.

HVAC caps and condenser tops – what to measure

  • Diameter of cap and any plan-view dents. State cap diameter and dent diameter. Example: "Condenser cap 12.0 in diameter; two dents at 1.25 in and 0.75 in."
  • Deformation of the flange where the cap meets the housing. Measure and photo any lifted flange more than 1/8 in.
  • Fasteners and weld points. Photograph stripped screws, split seals, or punctures.

For rooftop condensers note elevation and access route for safety reviews. Provide a photo showing the unit relative to eaves and parapet walls.

Flashings and trim – what to record

Flashings frequently crease and separate at overlaps. Record the length of separation in inches and the nearest roof coordinate. Photograph both sides of the flashing seam where feasible.

Trim failures to note: edge curl, paint breach exposing substrate, fastener pull-through, and folded edges that no longer overlap per manufacturer clearances. Measure exposed substrate widths and photo at both ends of the exposed run.

Sample report entries you can use

  • Gutter–north elevation–near downspout A: 1.00 in diameter impact dent located 12.3 ft east of downspout. Depth measured 3/32 in. 26-ga aluminum, white paint, paint fracture present. Photos 01–04 attached. GPS 35.46789, -97.51623. Time 2025-06-12T17:23:18Z.

  • Condenser cap–rear unit: cap diameter 12.0 in. Two impacts measured at 1.25 in and 0.75 in. Flange lifted 1/8 in at access side. Fastener heads intact. Photos 05–08 attached. GPS 35.46792, -97.51627.

  • Eave flashing–southwest corner: 6 in run with exposed substrate. Separation at overlap measured 1.5 in at largest point. Paint abrasion observed along entire run. Photos 09–11 attached. GPS 35.46801, -97.51640.

Cross-referencing NOAA and radar-derived data

Note the inspection time relative to reported hail onset. Cross-check with NEXRAD hail detection or NOAA MRMS radar-derived reports for the nearest storm cell. Record the reported hail-size range for the time window that included the property. Avoid claiming causation. Present the radar-derived hail report as contextual data.

Quick checklist for field teams

  • Carry caliper, small metric/imperial ruler, scale card, and a coin set for quick references.
  • Preserve full EXIF on photos; export CSV if an app strips metadata.
  • Always capture wide, medium, close-up with scale, and attachment detail.
  • Record GPS to five decimal places and device-synced timestamps.
  • State material gauge, finish, and approximate install year if known.
  • Use the NWS coin-size object scale when colloquial terms appear in spotter or homeowner reports; always include the inch value.

Documenting soft-metal hail damage requires measurement discipline and consistent photo standards. Clear notes and precise photos reduce ambiguity during review. Follow the steps above for defensible, repeatable documentation on gutters, HVAC caps, flashings, and trim.

Get storm alerts when it matters.

When the next hail storm hits your area, you'll be the first contractor with the address list. Sign up free – no credit card required.